Technical data
| Standard wiring | Plug'n Wire |
---|
Type | KRYPTON E3 | KRYPTON E5 | KRYPTON E10 | KRYPTON H10 | KRYPTON E20 | KRYPTON H20 |
Product number | 22 0009 | 22 0000 | 22 0001 | 22 0200 | 22 0002 | 22 0201 |
Installation | | | | | | |
Control panel installation | x | x | x | | x | |
Mounting rail | | | | x | | x |
Display | | | | | | |
3 numbers | x | | | | | |
4 numbers | | x | x | x | x | x |
7/8 numbers (energy) | | x | x | x | x | x |
Bar charts | x | | x | | x | |
3 numbers | x | | | x | | x |
4 numbers | | x | x | | x | |
Measurands | | | | | | |
Voltage | x | x | x | x | x | x |
Current | x | x | x | x | x | x |
Frequency | x | x | x | x | x | x |
Active power | | x | x | x | x | x |
Reactive power | | x | x | x | x | x |
Apparent power | | x | x | x | x | x |
Active energy | | x | x | x | x | x |
Reactive energy | | | x | x | x | x |
Apparent energy | | | x | x | x | x |
Power factor | | x | x | x | x | x |
Harmonic distortion factor | | | x | | x | |
Communication | | | | | | |
RS 485 Modbus RTU | | | x | x | x | x |
S0 interface | | x | x | | x | x |
Krypton multimeter E3
Performance characteristics
- 3 Ø voltage (TRMS)
- 3 Ø current (TRMS)
- Frequency
- Operating hours counter
- Programmable current/voltage transformer (primary only)
- Additional bar chart display of current in %
- Speed
Item | Item-No. |
Krypton multimeter E3 | 22 0009 |
Krypton multimeter E5
Performance characteristics
- 3 Ø voltage (TRMS)
- 3 Ø current (TRMS)
- 3 Ø power factor
- 3 Ø active power, reactive power, apparent power
- Active energy
- Frequency
- Programmable current/voltage transformer (primary only)
- Harmonic distortion factor
- with pulse output
Item | Item-No. |
Krypton multimeter E5 with S0 interface | 22 0000 |
Krypton multimeter E10
Performance characteristics
- 3 Ø voltage (TRMS)
- 3 Ø current (TRMS)
- 3 Ø power factor
- 3 Ø active power, reactive power, apparent power
- Active energy, reactive energy, apparent energy
- Frequency
- Programmable current/voltage transformer
- Harmonic distortion factor
- Additional bar chart display of current in %
- with Modbus RTU (RS485) interface
- with pulse output
Item | Item-No. |
Krypton multimeter E10 with S0 and RS485 (Modbus RTU) | 22 0001 |
Krypton multimeter H10
Performance characteristics
- 3 Ø voltage (TRMS)
- 3 Ø current (TRMS)
- 3 Ø power factor
- 3 Ø active power, reactive power, apparent power
- Active energy, reactive energy, apparent energy
- Frequency
- Programmable current/voltage transformer
- with Modbus RTU (RS485) interface
Item | Item-No. |
Krypton multimeter H10 with RS485 (Modbus RTU) | 22 0200 |
Sortirajte kao
Prikaz po stranici
Number of pieces in the package 1
Number of pieces in the package 1
Number of pieces in the package 1