Item | Item-No. | kg/pc. | Packaging |
Clamp strap 2,5-50mm2 output at bottom end | 20 9010 | 0,9 | 1 |
Clamp strap 2,5-50mm2 output at top end | 20 9011 | 0,9 | 1 |
Monitoring switch for switching status | 200852 000 | 0,03 | 1 |
Item | Item-No. | kg/pc. | Packaging |
Clamp strap 2,5-70mm2 output at bottom end | 20 8010 | 0,9 | 1 |
Clamp strap 2,5-70mm2 output at top end | 20 8011 | 0,9 | 1 |
Clamp strap 2.5-70 mm² output at bottom end | 20 8070 | 1,05 | 1 |
with electronic fuse monitoring | |||
Clamp strap 2.5-70 mm² output at top end | 20 8071 | 1,05 | 1 |
with electronic fuse monitoring | |||
Terminal screw M8 output at bottom end | 20 8012 | 0,9 | 1 |
Terminal screw M8 output at top end | 20 8013 | 0,9 | 1 |
Attachable connection space extension | 20 0148 | 0,02 | 1 |
Monitoring switch for switching status | 20 0852 | 0,01 | 1 |
Item | Item-No. | kg/pc. | Packaging |
Terminal screw M10 output at bottom end | 20 8110 | 2,5 | 1 |
Terminal screw M10 output at top end | 20 8111 | 2,5 | 1 |
Clamp straps 70-150mm2 (Set) | 20 0420 | 0,01 | 1 |
Attachable connection space extension | 20 1148 | 0,02 | 1 |
Monitoring switch for switching status | 20 1852 | 0,01 | 1 |
Item | Item-No. | kg/pc. | Packaging |
Terminal screw M10 output at bottom end | 20 8210 | 4,5 | 1 |
Terminal screw M10 output at top end | 20 8211 | 4,5 | 1 |
Clamp straps 120-240mm2 (Set) | 20 1237 | 0,25 | 1 |
Attachable connection space extension | 20 2148 | 0,02 | 1 |
Monitoring switch for switching status | 20 1852 | 0,01 | 1 |
NH 000 | NH 00 | NH 1 | NH 2 | ||||||||||
No. of poles | 3 | 3 | 3 | 3 | |||||||||
Conventional free air thermal current links NH Ith | 125A | 160A | 250A | 400A | |||||||||
Rated operational voltage Ue | 690V | 690V | 690V | 690V | |||||||||
Rated insulation voltage Ui | 1000V | 1000V | 1000V | 1000V | |||||||||
Rated impulse withstand voltage Uimp | 6kV | 8kV | 8kV | 12kV | |||||||||
Utilization category | AC 21B | AC 23B | DC 22B | AC 23B | AC 22B | DC 22B | AC 23B | AC 22B | DC 22B | AC 23B | DC 21B | DC 22B | |
Rated operational current Ie (A) | 125 | 125 | 100 | 160 | 160 | 160 | 250 | 250 | 250 | 400 | 400 | 400 | |
Rated operational voltage Ue (A) | 690 | 400 | 250 | 690 | 400 | 250 | 400 | 690 | 250 | 690 | 440 | 220 | |
Conventional nominal impact short circuit current | 690V 400V | 80kA 80kA | 80kA 80kA | 20kA 20kA | 80kA 100kA | 80kA 100kA | 20kA 20kA | 80kA 100kA | 80kA 100kA | 25kA 25kA | 80kA 100kA | 15kA 15kA | 20kA 20kA |
Rated short circuit making capacity | 690V 400V | 35kA 80kA | 50kA 80kA | 20kA 20kA | 80kA 100kA | 80kA 100kA | 20kA 20kA | 80kA 100kA | 80kA 100kA | 25kA 25kA | 80kA 100kA | 15kA 15kA | 20kA 20kA |
Rated operational frequency | 50-60 | 50-60 | 50-60 | - | 50-60 | - | 50-60 | ||||||
Degree of protection | IP 20 | IP 20 | IP 20 | IP 20 | |||||||||
Environment temperature tolerence °C | -25°C bis +55°C |